Electrically Heated Static Reduction Test Apparatus
according to the requirements of ISO 7992 and ISO 11256 for reduction determination of iron ore pellets
Technical Data
- Furnace designation:
- electrically heated reduction test apparatus
- Rated furnace temperature:
- 1,100 °C
- Heating:
- heating elements on fibre ceramic modules
- Number of heating zones:
- 3
Purpose
The electrically heated reduction test apparatus under load serves as static iron ore determination device acc. to ISO 7992 and ISO 11256 and can alse be used - without pressure - for different other ISO tests, e.g. ISO 11258, ISO 4695, etc.
Furnace Description
According to the ISO standards the reduction test apparatus consists of the pit furnace, the retort, the measuring and control station, the process gas control and the weighing equipment.
The reduction furnace is constructed as vertical tube furnace. The retort including pressure device hangs freely swinging inside the furnace below the balance. The furnace, the balance with the retort are built into a shock-resistant frame mount.
The temperature regulation as well as the gas control is done by a SIEMENS S7-PLC system control. Only the overtemperature safety circuits are designed acc. to the regulations for hardware controllers.
The gas regulation per gas circuit is equipped with pressure reducer, precision pressure regulator, flowmeter with visible floated element, gas mass flow regulator as well as magnetic valves. Through the built-in gas pre-heating unit the process gas is led into the reduction tube.
In order to move the balance laterally it is mounted on two linear carriages on the top of the frame mount.
- indication range (measuring range):
- 0.1 g to 64,000 g
- indication accuracy:
- 1 g
The tumbler drums acc. to ISO 11256 or similar test drums are delivered ready for connection and with protection equipment.
If you should need external iron ore determinations or assistance
with your own iron ore or coke determinations, you can be supported by
”Studiengesellschaft für Eisenerzaufbereitung SGA”
Grubenstrasse 5
D-38704 Liebenburg-Othfresen
Tel. (+49) 5346 / 9901-0 - Email: sga@sga-liebenburg.de
Fax (+49) 5346 / 9901-20 - Internet: www.sga-liebenburg.de